R3261/R3361 OPT.02/OPT.72. R3261/R3361 Series OPT.15 Hand Book. Preview of ADVANTEST R3261 R3361 SM [1st page] Click on the link for free download! This file is downloadable free of charge.processing.
KE5FX GPIB Toolkit Welcome to the GPIB Toolkit! The GPIB Toolkit is a collection of free Windows utilities that will help you make and record research-quality measurements with GPIB-based electronic test equipment. This is version 1.977 of the Toolkit, released October 2, 2018. For troubleshooting help and additional application notes, check the. The GPIB Toolkit is provided with full C source code for public- and private-sector, educational and Amateur Radio / hobbyist use. Comments and feedback are always welcome.
John Miles, KE5FX Note: As of July 2016, some false positives have been reported from certain virus scanners including Microsoft Security Essentials/Windows Defender. As long as the confirmation dialog includes a valid for Miles Design LLC, the file's code signature is intact, and you can safely disregard these warnings. This issue appears to have been resolved in the 1.225.1983.0 antivirus definition update. 7470.EXE is a Win32-based emulator for the HP 7470A plotter.
See its for more information. PN.EXE is an automated phase-noise measurement utility for HP, Tektronix, and Advantest spectrum analyzers. See its for more information.
SSM.EXE is a spectrum surveillance monitor application for HP, Tektronix, and Advantest spectrum analyzers, as well as Signal Hound USB spectrum analyzers. See its for more information. PROLOGIX.EXE allows you to select and configure a Prologix GPIB-USB or GPIB-ETHERNET adapter for use with the GPIB Toolkit applications.
It can also be used to select a National Instruments adapter, or to configure the GPIB Toolkit to work with an otherwise-unsupported TCP/IP or serial adapter. Most of the GPIB Toolkit applications support both Prologix and National Instruments GPIB adapters. By default, the Toolkit expects to find a National Instruments device at GPIB0.
When using a Prologix adapter, it's necessary to edit the CONNECT.INI file to tell the GPIB Toolkit where to find the Prologix adapter's virtual serial port or network address. This task is easy to accomplish with PROLOGIX.EXE. Simply run the program, select the Prologix or National Instruments adapter in the device list, and press the Update CONNECT.INI button. (Be sure to exit from PROLOGIX.EXE before attempting to run any other GPIB Toolkit application.) You can use the Edit CONNECT.INI button in PROLOGIX.EXE as a convenient way to modify your existing GPIB configuration manually, regardless of whether or not you're using a Prologix adapter.
Editing the file also gives you access to additional options for troubleshooting and optimization. See the comments in CONNECT.INI for more information. Beginning with the V1.50 release of the GPIB Toolkit, it is no longer necessary to select Device or Controller mode in PROLOGIX.EXE unless you wish to use the optional Terminal or Advanced Settings controls.
Each Toolkit application will configure the Prologix adapter's mode and address settings as needed. Usage examples: prologix Run with no command-line options for normal enumeration of all Prologix GPIB-USB, GPIB-ETHERNET, and National Instruments adapters prologix -noni Don't attempt to enumerate National Instruments adapters (useful if error messages are reported after a partial NI488.2 driver uninstallation) prologix -nonet Don't issue UDP broadcasts to detect Prologix GPIB-ETHERNET adapters VNA.EXE allows you to save and load control/calibration states for HP 8753, HP 8510, and HP 8720-series vector network analyzers.
Touchstone.S2P files can also be acquired from these models, as well as from the FieldFox portables. VNA.EXE can eliminate the need for a disk drive in many cases.
Release 1.00 of 5-Feb-13. Fixed some compatibility issues with Prologix GPIB-USB and GPIB-ETHERNET adapters Release 1.10 of 23-May-13. Added 'Save.S2P file' button Release 1.20 of 15-Jun-13.S2P export functionality verified compatible with HP 8510B. Renamed 8753.EXE to VNA.EXE to reflect support for multiple instruments Release 1.30 of 28-Aug-13.
Added the ability to export.S2P data in dB/angle or real/imaginary format as well as the default magnitude/angle format. Added the ability to specify the reference resistance for saved.S2P files Release 1.40 of 28-Sep-14.
Added progress indicator for lengthy operations. On 8753-series VNAs, the.S2P export function now restores the previously-active parameter when finished. Previous versions left S22 active. Improved reliability of.S2P export function when using Prologix adapters Release 1.50 of 30-Sep-14.
Support for saving/recalling instrument states and calibration data on HP 8510 series VNAs (tested on HP 8510C). Added Factory preset button. More reliability improvements for Prologix adapters Release 1.51 of 5-Oct-14.S2P export function now supports all sweep types on 8753- and 8720-series VNAs, including log and list sweeps. Only linear sweeps are supported on 8510 models.
Advantest Corporation TR5821 Counter Manufacturer Model: TR5821 Date: 1982 Category: Group: Description: Information: The /5822/5823/5823H are compact, inexpensive universal counters with the capabilities comparable to medium-scale counters. These are the It became possible to process data with a self-diagnostic function and various operations (by using TR1644). Since GPIB, BCD (TTL) output, and analog output (D/A converter) are available, these equipments can support various system. Is a universal that can measure frequencies of up to 120 MHz, and can display results in arbitrary form with TR1644 (an extra-cost option). The has the same functions as the plus a built-in GPIB interface, and the functions of the include an ultrahigh-frequency measurement (1.3 GHz) and a burst signal measurement in addition to the functions of the. The is provided with the high-stability (aging rate: 5 x l0 “8/day) as a standard feature plus the capabilities of the.